Double tab connectors
DFL 6,3
AI
TWO TABS.
6.3 MM.
CAPACITOR DISCHARGE.

AI
| Type | DFL 6,3 – double earth tab connector |
| Welding process | Tip ignition / capacitor discharge |
| Tab width b₁ | 6.3 ±0.1 mm |
| Material thickness c | 0,8 ±0,05 mm |
| Height l | 12 ±0.8 mm |
| materials | Steel, stainless steel, brass and aluminium according to the dimensional sheet |

AI
DFL 6,3 double tab connectors for capacitor discharge welding.
The manufacturer’s dimensional sheet lists copper-plated steel 4.8, stainless steel A2-50, brass CuZn37 and aluminium AlMg3. Other materials are possible by agreement.
The ignition tip melts during welding. The welding base and both connector tabs remain intact.
DFL 6,3 double tab connectors
Dimensions according to the manufacturer’s dimensional sheet
| Dimension | Value in mm |
|---|---|
| c ±0.05 | 0,8 |
| l ±0.8 | 12 |
| l₁ ±0.2 | 8 |
| d ±0.1 | 1,5 |
| b ±0.2 | 8 |
| b₁ ±0.1 | 6,3 |
| g ±0.8 | 10 |
Approximate weight: 1,34 kg per 1.000 steel pieces (St. 37), calculated using 7,85 kg/dm³.
| Material | Designation according to the dimensional sheet | Order code |
|---|---|---|
| Steel | 4.8 / St. 37, copper-plated | 01-063-0011 |
| Stainless steel | A2-50 / 1.4301 | 02-063-0011 |
| Brass | CuZn37 / MS 63 | 03-063-0011 |
| Aluminium | AlMg3 | 04-063-0011 |
Order enquiry
Please specify type DFL 6,3, material or order code, and quantity. Other materials and special versions are possible by agreement.
Applications for
DFL 6,3 double tab connectors

Control cabinet & enclosure manufacturing

General sheet metal fabrication

Electrical engineering & electronics

Equipment manufacturing

Facade & metal construction

Medical & laboratory technology

AI
Stud welding
with capacitor discharge
Still unsure which stud to choose?
Find the right solution for your application.
Equipment for
DFL 6,3 double tab connectors
Frequently asked questions
about DFL 6,3 double tab connectors
What does DFL 6,3 mean?
DFL 6,3 denotes the double earth tab connector with a 6.3 mm tab width. Further dimensions and tolerances are specified in the manufacturer’s dimensional sheet.
Which materials are available?
The manufacturer’s dimensional sheet lists copper-plated steel 4.8, stainless steel A2-50, brass CuZn37 and aluminium AlMg3. Other materials are possible by agreement.
What is the function of the ignition tip?
The ignition tip on the welding base initiates the welding process and melts during it. The geometry with two connector tabs and the welding base remain intact.
What changes during welding?
The ignition tip melts and the welding base is joined to the workpiece. The original drawing shows the states before and after welding. The DFL dimensional sheet does not specify a general reduction in length during welding.
What should be considered when selecting the connector?
The connector, material, base material, installation space and welding task must be compatible. Suitability for the specific electrical and mechanical application must be checked against its requirements.
Are ceramic ferrules required?
DFL 6,3 is processed using capacitor discharge welding. RF ceramic ferrules are not used with this process.
Which equipment is suitable for DFL 6,3?
The manufacturer’s page lists CONTACT-M, CDP-99M and the RAPIDOR QF automatic welding head as examples. A suitable holder, process and parameters are selected for the component and material.
Are special versions available?
Other materials and special versions are possible by agreement. Please send the required geometry, material, quantity and application requirements.

Double tab connectors to
your requirements
AI